Portable Gas/Diesel Systems

Your Air is our Business

Portable Gas/Diesel Systems

Our portable units are built tough for marine use. Powder coated aluminium frames and all stainless steel hardware ensure your system can withstand the elements for years to come.

Standard Features

  • Powder Coated Aluminum Frame With Vibration Isolation of Motor
  • Pressure Switch Activated Shutdown
  • Reliable Honda® gas Engine or Kubota® Diesel Engine
  • Interstage and Final Stage Safety Relief Valves
  • Interstage and Final Oil/Water Separators
  • Discharge Pressure Gauge
  • Continuous Duty Operation
  • CRN Purification and Separator Towers
  • System Air Quality Meets “Grade E” and CSA Standards Z180.1 & Z94.4
  • All Stainless Steel Tube Plumbing to CSA Standards B31 & B51
  • Pressure Maintaining And Check Valves To Maximize Purification Life
  • 5’ Fill Whip (SCUBA/SCBA)

*not all standard features available on the MCH6G

Options

  • Low Oil Shutdown
  • Electric Start
  • Digital Tachometer/Hour Meter

Gas Systems

Model

SCFM

HP

PSI

Weight

Dimensions

Stage

Purification

MCH6G*

4.2

3.5

4800

85lbs

28”L x 13”D x 15”H

4

5,000CUFT

C55-GH

6.6

5

5000

250lbs

43”L x 20”D x 22”H

3

15,000CUFT

C90-GH

10.8

9.0

5000

250lbs

43”L x 20”D x 22”H

3

30,000CUFT

C90H-GH

10.8

9.0

6000

260lbs

43”L x 20”D x 22”H

3

30,000CUFT

Diesel Systems

Model

SCFM

HP

PSI

Stage

Purification

C55-D

6.6

5

5000

3

15,000CUFT

C90-D

10.8

7.5

5000

3

30,000CUFT

C90H-D

10.8

7.5

6000

3

30,000CUFT

M13-D

14

10

6000

4

40,000CUFT

M17-D

19

15

6000

4

70,000CUFT

M25-D

26

20

6000

4

90,000CUFT

*All our diesel drive compressor systems include electric start and battery.

Hydraulic Drive Compressors

We offer hydraulic drive compressor systems with either a close coupled drive system to save space or a standard side by side belt drive. These systems are ideal for use on fire apparatus and marine operations where electrical power isn’t available. Our systems come complete with overflow valves to prevent over revving the motor or compressor.

Hydraulic Systems

Model

SCFM

HP

PSI

Weight & Dimensions

Stage

Purification

C55-HY

5

5

5000

Vary with drive layout

3

15,000CUFT

C90-HY

9

7.5

5000

Vary with drive layout

3

30,000CUFT

C90H-HY

9

7.5

6000

Vary with drive layout

3

30,000CUFT

M13-HY

13

10

6000

Vary with drive layout

4

40,000CUFT

M17-HY

17

15

6000

Vary with drive layout

4

70,000CUFT

M25-HY

24

20

6000

Vary with drive layout

4

90,000CUFT